Stage 7

Economiser Audit

A practical review of economiser opportunity, damper behaviour, free-cooling usage, mixed-air plausibility, heating conflict, and source data quality.

StageBUILDING_INTELLIGENCE_STAGE_7_ECONOMISER_AUDIT
Versionstage7.economiser.1.0
Generated2026-06-22T13:53:38+1000
Sample window2026-06-08T13:53:26+1000 to 2026-06-22T13:53:26+1000
Lookback days14.0
HIGH
28

Equipment requiring immediate review.

MEDIUM
0

Equipment with findings worth checking.

SCORE
58

Average economiser summary score.

DATA
28

Equipment with data quality limits.

OPPORTUNITY
0.0

Total free-cooling opportunity hours.

MISSED
0.0

Opportunity hours where damper stayed below open threshold.

MECH COOL
0.0

Mechanical cooling during free-cooling opportunity.

EQUIPMENT
28

Economiser equipment groups analysed.

How to read this report

Economiser opportunity means outside air appeared suitable for free cooling based on configured outside-air limits and return/outside-air delta.

Available not used means opportunity existed but the outside air damper was below the open threshold. Mechanical cooling during free cooling is worse, because cooling was active while free cooling was apparently available and not being used. Tiny tragedy, very Niagara.

Mixed air implausible means mixed air temperature sat outside the expected range between outside and return air, allowing the configured tolerance.

Outside air fallback status

Global OAT label GLOBAL_OUTSIDE_AIR_TEMP
Global OAT status DISABLED
Global OAT history
History ID fallback enabled true
Configured history ID history:/Site_Y_Supervisor/Outside$7cOutside_Air_Temp
History ID fallback status OK_HISTORY_ID_MATCHED

Top action findings

#1 ECONOMISER_DATA_NOT_READY

Chiller_02 | CHW_System/Chiller_02
HIGH
Score 45
Readiness LOW_ECONOMISER_READY
Data Quality PARTIAL
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source ASSUMED_ALL_BUCKETS_NO_STATUS
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history. No status history was available. Economiser calculations assumed all analysed buckets were operating time.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID STATUS_OPTIONAL_NOT_AVAILABLE NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED RETURN_AIR_TEMP_CARRY_FORWARD_USED STATUS_HISTORY_NOT_AVAILABLE

#2 ECONOMISER_DATA_NOT_READY

AHU_05 | Pool_Hall_Air/AHU_05
HIGH
Score 45
Readiness LOW_ECONOMISER_READY
Data Quality PARTIAL
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source ASSUMED_ALL_BUCKETS_NO_STATUS
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history. No status history was available. Economiser calculations assumed all analysed buckets were operating time.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID STATUS_OPTIONAL_NOT_AVAILABLE NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED STATUS_HISTORY_NOT_AVAILABLE

#3 ECONOMISER_DATA_NOT_READY

CHWP_01 | CHW_System/CHWP_01
HIGH
Score 60
Readiness LOW_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED

#4 ECONOMISER_DATA_NOT_READY

CHWP_02 | CHW_System/CHWP_02
HIGH
Score 60
Readiness LOW_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED

#5 ECONOMISER_DATA_NOT_READY

Fluid_Cooler | Fluid_Cooler
HIGH
Score 60
Readiness LOW_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED

#6 ECONOMISER_DATA_NOT_READY

FCU_01 | Ground_Floor_FCUs/FCU_01
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#7 ECONOMISER_DATA_NOT_READY

FCU_02 | Ground_Floor_FCUs/FCU_02
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#8 ECONOMISER_DATA_NOT_READY

FCU_03 | Ground_Floor_FCUs/FCU_03
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#9 ECONOMISER_DATA_NOT_READY

FCU_04 | Ground_Floor_FCUs/FCU_04
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#10 ECONOMISER_DATA_NOT_READY

FCU_05 | Ground_Floor_FCUs/FCU_05
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#11 ECONOMISER_DATA_NOT_READY

FCU_06 | Ground_Floor_FCUs/FCU_06
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#12 ECONOMISER_DATA_NOT_READY

FCU_07 | Ground_Floor_FCUs/FCU_07
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#13 ECONOMISER_DATA_NOT_READY

FCU_14 | Ground_Floor_FCUs/FCU_14
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#14 ECONOMISER_DATA_NOT_READY

HWP_01 | HW_System/HWP_01
HIGH
Score 60
Readiness LOW_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED

#15 ECONOMISER_DATA_NOT_READY

HWP_02 | HW_System/HWP_02
HIGH
Score 60
Readiness LOW_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED

#16 ECONOMISER_DATA_NOT_READY

HWP_03 | HW_System/HWP_03
HIGH
Score 60
Readiness LOW_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED

#17 ECONOMISER_DATA_NOT_READY

HWP_04 | HW_System/HWP_04
HIGH
Score 60
Readiness LOW_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED

#18 ECONOMISER_DATA_NOT_READY

PHWP_01 | HW_System/PHWP_01
HIGH
Score 60
Readiness LOW_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED

#19 ECONOMISER_DATA_NOT_READY

PHWP_02 | HW_System/PHWP_02
HIGH
Score 60
Readiness LOW_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED

#20 ECONOMISER_DATA_NOT_READY

PHWP_03 | HW_System/PHWP_03
HIGH
Score 60
Readiness LOW_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED

#21 ECONOMISER_DATA_NOT_READY

FCU_08 | Level_1_FCUs/FCU_08
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#22 ECONOMISER_DATA_NOT_READY

FCU_09 | Level_1_FCUs/FCU_09
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#23 ECONOMISER_DATA_NOT_READY

FCU_10 | Level_1_FCUs/FCU_10
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#24 ECONOMISER_DATA_NOT_READY

FCU_11 | Level_1_FCUs/FCU_11
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#25 ECONOMISER_DATA_NOT_READY

FCU_12 | Level_1_FCUs/FCU_12
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#26 ECONOMISER_DATA_NOT_READY

FCU_13 | Level_1_FCUs/FCU_13
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#27 ECONOMISER_DATA_NOT_READY

FCU_15 | Level_1_FCUs/FCU_15
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

#28 ECONOMISER_DATA_NOT_READY

FCU_16 | Level_1_FCUs/FCU_16
HIGH
Score 60
Readiness PARTIAL_ECONOMISER_READY
Data Quality GOOD_WITH_CARRY_FORWARD
Confidence NONE
Opportunity Hours 0.0
Available Not Used 0.0
Mechanical Cooling During Free Cooling 0.0
OA Damper Open Not Beneficial 0.0
Mixed Air Implausible 0.0
Heating With High OA 0.0
OAT Source HISTORY_ID_FALLBACK
Operating Hours Source STATUS_HISTORY
Recommendation: Economiser audit could not run because Stage 1 did not map enough economiser histories. Re-run Stage 1 with correct scope and synonyms if the points exist, configure a global outside air fallback, or configure the outsideAirTempHistoryId fallback where the history is mapped separately. Outside air temperature was supplied from the configured outsideAirTempHistoryId fallback because neither equipment-level mapping nor global ORD fallback resolved a usable history.
CAN_USE_OUTSIDE_AIR_TEMP_HISTORY_ID NO_ECONOMISER_CHECKS_AVAILABLE OUTSIDE_AIR_TEMP_HISTORY_ID_FALLBACK_USED OUTSIDE_AIR_TEMP_CARRY_FORWARD_USED SUPPLY_AIR_TEMP_CARRY_FORWARD_USED COOLING_VALVE_CARRY_FORWARD_USED HEATING_VALVE_CARRY_FORWARD_USED

Equipment summary

RankPriorityEquipmentScorePrimary FindingData QualityConfidenceOpportunity HoursAvailable Not UsedMechanical Cooling During Free CoolingOAT Source
1 HIGH Chiller_02
CHW_System/Chiller_02
45 ECONOMISER_DATA_NOT_READY PARTIAL NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
2 HIGH AHU_05
Pool_Hall_Air/AHU_05
45 ECONOMISER_DATA_NOT_READY PARTIAL NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
3 HIGH CHWP_01
CHW_System/CHWP_01
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
4 HIGH CHWP_02
CHW_System/CHWP_02
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
5 HIGH Fluid_Cooler
Fluid_Cooler
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
6 HIGH FCU_01
Ground_Floor_FCUs/FCU_01
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
7 HIGH FCU_02
Ground_Floor_FCUs/FCU_02
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
8 HIGH FCU_03
Ground_Floor_FCUs/FCU_03
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
9 HIGH FCU_04
Ground_Floor_FCUs/FCU_04
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
10 HIGH FCU_05
Ground_Floor_FCUs/FCU_05
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
11 HIGH FCU_06
Ground_Floor_FCUs/FCU_06
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
12 HIGH FCU_07
Ground_Floor_FCUs/FCU_07
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
13 HIGH FCU_14
Ground_Floor_FCUs/FCU_14
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
14 HIGH HWP_01
HW_System/HWP_01
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
15 HIGH HWP_02
HW_System/HWP_02
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
16 HIGH HWP_03
HW_System/HWP_03
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
17 HIGH HWP_04
HW_System/HWP_04
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
18 HIGH PHWP_01
HW_System/PHWP_01
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
19 HIGH PHWP_02
HW_System/PHWP_02
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
20 HIGH PHWP_03
HW_System/PHWP_03
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
21 HIGH FCU_08
Level_1_FCUs/FCU_08
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
22 HIGH FCU_09
Level_1_FCUs/FCU_09
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
23 HIGH FCU_10
Level_1_FCUs/FCU_10
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
24 HIGH FCU_11
Level_1_FCUs/FCU_11
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
25 HIGH FCU_12
Level_1_FCUs/FCU_12
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
26 HIGH FCU_13
Level_1_FCUs/FCU_13
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
27 HIGH FCU_15
Level_1_FCUs/FCU_15
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK
28 HIGH FCU_16
Level_1_FCUs/FCU_16
60 ECONOMISER_DATA_NOT_READY GOOD_WITH_CARRY_FORWARD NONE 0.0 0.0 0.0 HISTORY_ID_FALLBACK

Mapped history evidence

EquipmentOutside AirReturn AirMixed AirSupply AirOA DamperRA DamperCooling ValveHeating ValveStatus
Chiller_02 /Site_Y_Supervisor/Chiller_02$7cEvaporating_Pressure
AHU_05 /Site_Y_Supervisor/AHU_05$7cSupply_Air_Temp
CHWP_01 /Site_Y_Supervisor/CHWP_01$7cRun_Status
CHWP_02 /Site_Y_Supervisor/CHWP_02$7cRun_Status
Fluid_Cooler /Site_Y_Supervisor/Fluid_Cooler$7cFan_Status
FCU_01 /Site_Y/FCU_01_Supply_Air_Temp /Site_Y/FCU_01_Chilled_Water_Valve /Site_Y_Supervisor/FCU_01$7cHot_Water_Valve /Site_Y/FCU_01_Fan_Status
FCU_02 /Site_Y/FCU_02$20Supply_Air_Temp /Site_Y/FCU_02_Chilled_Water_Valve /Site_Y_Supervisor/FCU_02$7cHot_Water_Valve /Site_Y/FCU_02_Fan_Status
FCU_03 /Site_Y/FCU_03$20Supply_Air_Temp /Site_Y/FCU_03_Chilled_Water_Valve /Site_Y_Supervisor/FCU_03$7cHot_Water_Valve /Site_Y/FCU_03_Fan_Status
FCU_04 /Site_Y/FCU_04$20Supply_Air_Temp /Site_Y/FCU_04_Chilled_Water_Valve /Site_Y_Supervisor/FCU_04$7cHot_Water_Valve /Site_Y/FCU_04_Fan_Status
FCU_05 /Site_Y/FCU_05$20Supply_Air_Temp /Site_Y/FCU_05_Chilled_Water_Valve /Site_Y_Supervisor/FCU_05$7cHot_Water_Valve /Site_Y/FCU_05_Fan_Status
FCU_06 /Site_Y/FCU_06$20Supply_Air_Temp /Site_Y/FCU_06_Chilled_Water_Valve /Site_Y_Supervisor/FCU_06$7cHot_Water_Valve /Site_Y/FCU_06_Fan_Status
FCU_07 /Site_Y/FCU_07$20Supply_Air_Temp /Site_Y/FCU_07_Chilled_Water_Valve /Site_Y_Supervisor/FCU_07$7cHot_Water_Valve /Site_Y/FCU_07_Fan_Status
FCU_14 /Site_Y/FCU_14$20Supply_Air_Temp /Site_Y/FCU_14_Chilled_Water_Valve /Site_Y_Supervisor/FCU_14$7cHot_Water_Valve /Site_Y/FCU_14_Fan_Status
HWP_01 /Site_Y/HWP_01_Status
HWP_02 /Site_Y/HWP_02_Status
HWP_03 /Site_Y/HWP_03_Status
HWP_04 /Site_Y/HWP_04_Status
PHWP_01 /Site_Y_Supervisor/PHWP_01$7cRun_Status
PHWP_02 /Site_Y_Supervisor/PHWP_02$7cRun_Status
PHWP_03 /Site_Y_Supervisor/PHWP_03$7cRun_Status
FCU_08 /Site_Y/FCU_08$20Supply_Air_Temp /Site_Y/FCU_08_Chilled_Water_Valve /Site_Y_Supervisor/FCU_08$7cHot_Water_Valve /Site_Y/FCU_08_Fan_Status
FCU_09 /Site_Y/FCU_09$20Supply_Air_Temp /Site_Y/FCU_09_Chilled_Water_Valve /Site_Y_Supervisor/FCU_09$7cHot_Water_Valve /Site_Y/FCU_09_Fan_Status
FCU_10 /Site_Y/FCU_10$20Supply_Air_Temp /Site_Y/FCU_10_Chilled_Water_Valve /Site_Y_Supervisor/FCU_10$7cHot_Water_Valve /Site_Y/FCU_10_Fan_Status
FCU_11 /Site_Y/FCU_11$20Supply_Air_Temp /Site_Y/FCU_11_Chilled_Water_Valve /Site_Y_Supervisor/FCU_11$7cHot_Water_Valve /Site_Y/FCU_11_Fan_Status
FCU_12 /Site_Y/FCU_12_Supply_Air_Temp /Site_Y/FCU_12_Chilled_Water_Valve /Site_Y_Supervisor/FCU_12$7cHot_Water_Valve /Site_Y/FCU_12_Fan_Status
FCU_13 /Site_Y/FCU_13$20Supply_Air_Temp /Site_Y/FCU_13_Chilled_Water_Valve /Site_Y_Supervisor/FCU_13$7cHot_Water_Valve /Site_Y/FCU_13_Fan_Status
FCU_15 /Site_Y/FCU_15$20Supply_Air_Temp /Site_Y/FCU_15_Chilled_Water_Valve /Site_Y_Supervisor/FCU_15$7cHot_Water_Valve /Site_Y/FCU_15_Fan_Status
FCU_16 /Site_Y/FCU_16$20Supply_Air_Temp /Site_Y/FCU_16_Chilled_Water_Valve /Site_Y_Supervisor/FCU_16$7cHot_Water_Valve /Site_Y/FCU_16_Fan_Status